Rinnai · Tankless water heater

SEt Initial settings not yet confirmed

Low severity SENSEI RX/CX

What the control is telling you

Shown on first power-up of a SENSEI RX/CX unit, which ships configured for natural gas and indoor installation. The installer must confirm or change the initial settings before the heater is used.

Applies to: SENSEI RX/CX series only

Likely causes

  • Unit powered up for the first time
  • Factory default settings (natural gas, indoor) not yet confirmed by the installer
  • Initial settings need to be changed to match the actual installation

Test and repair steps

  1. Warning: Using the heater before the correct initial settings are selected creates a hazard that can cause injury or property damage. Only a trained, qualified professional should do the initial setup.
  2. Option 1 (recommended) confirm or change the initial settings from a smart device over Bluetooth Low Energy (BLE).
  3. Option 2 confirm or change the initial settings using the water heater's controller.
  4. See the "Initial Settings" section of installation manual 100000839 or 100000840 for full details.

Settings for these units

RX supply connection sizes · SENSEI RX/CX

ConnectionSize
Gas3/4 in. MNPT
Cold inlet3/4 in. MNPT
Hot outlet3/4 in. MNPT
Condensate drain1/2 in. MNPT

Vent connection: 2 in. nominal PVC/CPVC/PP or 3 in./5 in. concentric.

Full specs (input, flow, weight) are only on each model's spec sheet, not in this manual.

RX water quality limits · SENSEI RX/CX

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved CO2Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDSUp to 500 mg/L
ZincUp to 5 mg/L

Water damage beyond these limits is not covered by warranty.

Models that show this code

10 models in SENSEI RX/CX

CX160iCX199iCXP160iCXP199iRX130iRX160iRX180iRX199iRXP160iRXP199i

Other codes on the same units

  • 66 Bypass flow servo fault
  • 70 PC board fault
  • 71 Gas solenoid valve fault (SV0–SV4 on Non-SENSEI)
  • 72 Flame rod fault
  • FF Maintenance performed (history marker)
  • LC Scale build-up in heat exchanger (LC, LC0–LC9, 00)
  • SE Cascade diagnostic display (error on secondary unit)
  • SS Service Soon alert (also listed as 55)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.5. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.