LC Scale build-up in heat exchanger (LC, LC0–LC9, 00)
What the control is telling you
LC or LC0–LC9 means scale has built up in the heat exchanger and it must be flushed; in the maintenance code history it appears as 00. Newer units lock out until reset.
Applies to: SENSEI RX/CX Series, Non-SENSEI Series
Likely causes
- Scale build-up in the heat exchanger
- Untreated hard water
- Heat exchanger not flushed at the recommended interval
- Repeated temporary resets without flushing (LC# count rising)
Test and repair steps
- Flush the heat exchanger following the owner's manual procedure (section 6.3 on SENSEI RX/CX).
- Treat hard water to prevent further scale and heat exchanger damage.
- Non-SENSEI LC codes are the only codes that let the heater keep running; the display alternates LC and set temperature and the controller keeps beeping.
- Non-SENSEI older products reset LC by switching power off and back on.
- Newer Non-SENSEI and SENSEI RX/CX a built-in shutdown locks the heater out to prevent scale damage, so a reset is required.
- Temporary run until flushing press On/Off on the controller five times (within 5 s on RX/CX). The unit runs ~70 hrs then locks out again; display cycles set temp and LC#. E.g., LC2 = three 70-hr resets without flush.
- After flushing, SENSEI RX/CX LC clears automatically if the flush completes properly; if not, press PC board buttons A and B together for five seconds.
- After flushing, newer Non-SENSEI press PC board buttons A and B together for five seconds.
- The heater returns to normal and the LC# count resets to 0. This hard reset is not listed in the owner's/installation manual or tech sheet.
- SENSEI RX/CX Flushing history can be viewed in the Rinnai Central app.
Settings for these units
RX supply connection sizes · SENSEI RX/CX
| Connection | Size |
|---|---|
| Gas | 3/4 in. MNPT |
| Cold inlet | 3/4 in. MNPT |
| Hot outlet | 3/4 in. MNPT |
| Condensate drain | 1/2 in. MNPT |
Vent connection: 2 in. nominal PVC/CPVC/PP or 3 in./5 in. concentric.
Full specs (input, flow, weight) are only on each model's spec sheet, not in this manual.
RX water quality limits · SENSEI RX/CX
| Contaminant | Maximum level |
|---|---|
| Total hardness | Up to 200 mg/L |
| Aluminum | Up to 0.2 mg/L |
| Chlorides | Up to 250 mg/L |
| Copper | Up to 1.0 mg/L |
| Dissolved CO2 | Up to 15.0 mg/L |
| Iron | Up to 0.3 mg/L |
| Manganese | Up to 0.05 mg/L |
| pH | 6.5 to 8.5 |
| TDS | Up to 500 mg/L |
| Zinc | Up to 5 mg/L |
Water damage beyond these limits is not covered by warranty.
- RX water treatment and flushing by hardness · SENSEI RX/CX
- RX clearances to combustibles · SENSEI RX/CX
- RX temperature settings available · SENSEI RX/CX
- RUCS/RUS unit clearances · Non-SENSEI
- RUCS/RUS water quality limits · Non-SENSEI
Models that show this code
69 models in Non-SENSEI, RH180 hybrid, SENSEI RX/CX
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.67–68. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.