Rinnai · Tankless water heater

79 Water leakage detected

High severity Non-SENSEIRH180 hybrid

What the control is telling you

The internal leak detector has sensed water inside the cabinet, or the leak sensor/its wiring is faulty.

Applies to: Non-SENSEI Series

Likely causes

  • Leaking heat exchanger or internal piping
  • Water pooled on the cabinet bottom pan
  • Wet leak sensor
  • Loose, broken or damaged leak detector wiring
  • Failed leak sensor

Test and repair steps

  1. Inspect the leak detector wiring and connections for loose, broken or damaged parts.
  2. Check the heat exchanger and all internal piping for leaks.
  3. If no leak is found, look for water pooled on the bottom pan; wipe or blow it out, dry the leak sensor and restart the heater.
  4. If the cabinet is dry, unplug the sensor and fire the heater; if it runs with the sensor unplugged, replace the sensor and its screw.

Settings for these units

RUCS/RUS unit clearances · Non-SENSEI

LocationRUCS indoor to combustiblesRUCS indoor to non-combustiblesRUS outdoor to combustiblesRUS outdoor to non-combustibles
Top6 in. (152 mm) *2 in. (51 mm) *12 in. (305 mm)2 in. (51 mm)
Back0 in.0 in.0 in.0 in.
Front6 in. (152 mm)6 in. (152 mm)--
Front (panel)--24 in. (610 mm)0 in.
Front (exhaust)--24 in. (610 mm)24 in. (610 mm)
Sides2 in. (51 mm)1/2 in. (13 mm)6 in. (152 mm)1/8 in. (3.2 mm)
Ground/bottom12 in. (305 mm)12 in. (305 mm)12 in. (305 mm)2 in. (51 mm)
Vent0 in.0 in.--

0 in. from vent components and condensate drain line.

Service clearance 24 in. in front of the heater; closet installs need 6 in. (152 mm) in front.

RUCS/RUS water quality limits · Non-SENSEI

ContaminantMaximum level
Total hardnessUp to 200 mg / L
AluminumUp to 0.2 mg / L
ChloridesUp to 250 mg / L
CopperUp to 1.0 mg / L
Dissolved CO2Up to 15.0 mg / L or PPM
IronUp to 0.3 mg / L
ManganeseUp to 0.05 mg / L
pH6.5 to 8.5
TDSUp to 500 mg / L
ZincUp to 5 mg / L

Scale build-up shows as code LC# on a controller (LC on the status monitor without one); flush the heat exchanger.

ScaleCutter parts: 103000038 (system), 103000039 (refill).

Models that show this code

59 models in Non-SENSEI, RH180 hybrid

C199eC199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRH180RL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRU80eRU80iRU90eRU98eRU98iRUC80iRUC90iRUC98iRUCS65iRUCS75iRUR98eRUR98iRUS65eRUS75eV53DeV53eV65eV65iV75eV75iV94XiV94eV94i

Other codes on the same units

  • 65 Water flow control device (servo) fault
  • 70 PC board fault
  • 71 Gas solenoid valve fault (SV0–SV4 on Non-SENSEI)
  • 72 Flame rod fault
  • 73 Burner thermocouple fault
  • FE Flammable vapors detected
  • FF Maintenance performed (history marker)
  • LC Scale build-up in heat exchanger (LC, LC0–LC9, 00)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.62. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.