Rinnai · Tankless water heater

65 Water flow control device (servo) fault

Medium severity Non-SENSEIRH180 hybridSENSEI RX/CXSENSEI

What the control is telling you

The water flow control servo is faulty; the servo valve did not close during the bath fill function.

Applies to: SENSEI Series, SENSEI RX/CX Series, Non-SENSEI Series

Likely causes

  • Loose, broken or damaged servo wiring
  • Water flow control servo failed to close
  • Failed water flow control servo
  • Incorrect servo resistance or supply voltage at the PC board

Test and repair steps

  1. Inspect the harness from the water flow servo valve to the PC board for loose, broken or damaged connections.
  2. Cycle power off and on and see whether the code clears.
  3. Because the servo failed to close during bath fill, shut off the water flow right away and stop using the bath fill controller.
  4. Warning: Turn off the electrical, gas and water supply to the heater before continuing.
  5. Replace the water flow control servo.
  6. SENSEI At connector D: red #18–pink #20 = 44–52 Ω; white #16–blue #14 = 44–52 Ω; grey #30 (black near the board)–orange #12 = 12–14 VDC.
  7. SENSEI RX/CX At CN9: red #16–pink #17 and white #15–blue #14 = 40-60 Ω; grey #5–orange #9 = 11-13 VDC; grey #5–brown #13 = under 1 VDC with limiter on, 4-6 VDC with limiter off.

Settings for these units

RSC supply connection sizes · SENSEI

ConnectionSize
Gas3/4 in. NPT
Cold inlet3/4 in. NPT
Hot outlet3/4 in. NPT
Condensate drain1/2 in. NPT
Pressure relief valveM33 thread

The PRV and its adapter come in the box; PRV must be rated 150 psi and at least the heater Btu/h.

Condensate drain line must stay at least 1/2 in. over its whole length.

RSC water quality limits · SENSEI

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved CO2Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDSUp to 500 mg/L
ZincUp to 5 mg/L

Damage from water above these limits is not covered by warranty.

Hard water should be treated; use the Service Soon (SS) reminder (parameter 03) for flushing intervals.

Models that show this code

89 models in Non-SENSEI, RH180 hybrid, SENSEI RX/CX, SENSEI

C199eC199iCU160eCU160iCU199eCU199iCX160iCX199iCXP160iCXP199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRH180RL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRSC160eRSC160iRSC199eRSC199iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRU80eRU80iRU90eRU98e

Other codes on the same units

  • 57 Burner overheat bi-metal switch open
  • 58 Secondary heat exchanger bi-metal switch open
  • 61 Combustion fan motor fault
  • 63 Recirculation low flow
  • 66 Bypass flow servo fault
  • 70 PC board fault
  • 71 Gas solenoid valve fault (SV0–SV4 on Non-SENSEI)
  • 72 Flame rod fault

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.55. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.