Rinnai · Tankless water heater

61 Combustion fan motor fault

High severity Non-SENSEIRH180 hybridSENSEI RX/CXSENSEI

What the control is telling you

The combustion fan motor is not operating correctly, due to wiring, a seized or obstructed blower, open windings, incorrect supply voltage or a control board fault.

Applies to: SENSEI Series, SENSEI RX/CX Series, Non-SENSEI Series

Likely causes

  • Loose, broken or damaged fan motor wiring
  • Blower wheel binding or debris in the fan housing
  • Check valve behind the fan stuck closed (SENSEI / SENSEI RX/CX)
  • Open fan motor windings
  • Incorrect fan supply voltage from the PC board
  • Faulty PC board

Test and repair steps

  1. Warning: Turn off power and gas before servicing the fan. Never plug or unplug the motor with power applied; doing so can damage the fan motor and other parts.
  2. Inspect the harness from the fan motor to the PC board for loose, broken or damaged connections.
  3. With power and gas off, remove the fan motor and confirm the blower wheel spins freely.
  4. Check the fan housing for debris that could stop the wheel from turning.
  5. SENSEI / SENSEI RX/CX Make sure the check valve behind the fan motor is not stuck closed.
  6. Measure fan motor winding resistance against the Technical Data Sheet (behind the front cover) or service manual; replace the motor if windings are open.
  7. SENSEI RX/CX With the unit running, measure at CN7: red #1–black #2 = 7-48 VDC; white #4–black #2 = 2-14 VDC; yellow #3–black #2 = 11-13 VDC (see Electric Circuit Table/wiring diagram).
  8. If windings and voltage are within spec and the fan turns freely, replace the PC board.

Settings for these units

RSC supply connection sizes · SENSEI

ConnectionSize
Gas3/4 in. NPT
Cold inlet3/4 in. NPT
Hot outlet3/4 in. NPT
Condensate drain1/2 in. NPT
Pressure relief valveM33 thread

The PRV and its adapter come in the box; PRV must be rated 150 psi and at least the heater Btu/h.

Condensate drain line must stay at least 1/2 in. over its whole length.

RSC water quality limits · SENSEI

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved CO2Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDSUp to 500 mg/L
ZincUp to 5 mg/L

Damage from water above these limits is not covered by warranty.

Hard water should be treated; use the Service Soon (SS) reminder (parameter 03) for flushing intervals.

Models that show this code

89 models in Non-SENSEI, RH180 hybrid, SENSEI RX/CX, SENSEI

C199eC199iCU160eCU160iCU199eCU199iCX160iCX199iCXP160iCXP199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRH180RL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRSC160eRSC160iRSC199eRSC199iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRU80eRU80iRU90eRU98e

Other codes on the same units

  • 52 Gas valve / modulating solenoid valve (POV) signal fault
  • 54 High exhaust gas temperature
  • 57 Burner overheat bi-metal switch open
  • 58 Secondary heat exchanger bi-metal switch open
  • 63 Recirculation low flow
  • 65 Water flow control device (servo) fault
  • 66 Bypass flow servo fault
  • 70 PC board fault

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.52. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.