Rinnai · Tankless water heater

19 Electrical grounding / DC circuit short

High severity Non-SENSEIRH180 hybridSENSEI RX/CXSENSEI

What the control is telling you

Code 19 showing right after water flow starts (no visible flame) indicates an electrical short in a component on the DC circuit.

Applies to: SENSEI Series; SENSEI RX/CX Series; Non-SENSEI Series

Likely causes

  • Shorted wiring harness
  • Shorted water flow control valve
  • Shorted bypass valve
  • Short in another DC-circuit component

Test and repair steps

  1. Confirm the code appears immediately when water flow begins with no flame visible in the burner box.
  2. Disconnect DC-circuit components (harnesses, water flow control, bypass valve, etc.) one at a time and try to fire the unit after each.
  3. If the unit cycles on three times after a component is unplugged, that component holds the short; repair or replace it.

Settings for these units

RSC supply connection sizes · SENSEI

ConnectionSize
Gas3/4 in. NPT
Cold inlet3/4 in. NPT
Hot outlet3/4 in. NPT
Condensate drain1/2 in. NPT
Pressure relief valveM33 thread

The PRV and its adapter come in the box; PRV must be rated 150 psi and at least the heater Btu/h.

Condensate drain line must stay at least 1/2 in. over its whole length.

RSC water quality limits · SENSEI

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved CO2Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDSUp to 500 mg/L
ZincUp to 5 mg/L

Damage from water above these limits is not covered by warranty.

Hard water should be treated; use the Service Soon (SS) reminder (parameter 03) for flushing intervals.

Models that show this code

89 models in Non-SENSEI, RH180 hybrid, SENSEI RX/CX, SENSEI

C199eC199iCU160eCU160iCU199eCU199iCX160iCX199iCXP160iCXP199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRH180RL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRSC160eRSC160iRSC199eRSC199iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRU80eRU80iRU90eRU98e

Other codes on the same units

  • 15 Venturi control fault
  • 16 Outlet water over-temperature safety shutdown
  • 17 Venturi blockage
  • 18 Gas valve air/fuel adjustment limit reached
  • 21 PC board data transfer error
  • 22 Gas valve adjustment fault
  • 25 Condensate pump failure or clogged drain
  • 30 Flammable vapor sensor activated or faulty

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.31. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.