KeepRite · Furnace
5 Flame sensed with gas valve off
What the control is telling you
The board sees flame while the gas valve should be closed. The inducer keeps running until the fault clears.
Applies to: KeepRite (F/G)9MXE single-stage and (F/G)9MXT two-stage 95% furnaces
Likely causes
- Gas valve stuck open or leaking through
Test and repair steps
- Warning: shut off the manual gas valve if flame is present with no heat call.
- Confirm the gas valve has no 24 V when no flame is expected.
- Replace a gas valve that passes gas while de-energized.
Settings for these units
- Filter size by casing width · KeepRite (F/G)96VTN Two-Stage Variable-Speed Furnace
Models that show this code
16 models in KeepRite (F/G)9MXE Single-Stage Furnace, KeepRite (F/G)9MXT Two-Stage Furnace
Other codes on the same units
- 1+2 Blower running after power-up (normal)
- 2 Pressure switch stuck closed (did not open)
- 3 Pressure switch did not close or reopened
- 4 Limit or rollout circuit open
- 6 Flame not proved during ignition trial
- 6+1 Ignition lockout after 4 failed tries
- 7 Limit circuit lockout
- 8 Gas heating lockout - manual reset needed
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: KeepRite/ICP (F/G)9MXE Service and Technical Support Manual 440 04 4311 09, Fig. 16 troubleshooting flow chart, p.24-25; KeepRite/ICP (F/G)9MXT Service and Technical Support Manual 440 04 4321 10, Fig. 16, p.24-25. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.