Lennox · Furnace

E164 Low GWP test mode active

Low severity Lennox ML180UHE

What the control is telling you

Shown when someone pressed the LGWP test button. Not a fault - normal operation resumes and the code clears by itself after 1 minute.

Applies to: ML180UHEK (R-454B era) single-stage 80% furnaces with integrated control 107792-XX (ML180UH045/070/090/110/135, incl. low-NOx X models)

Likely causes

  • LGWP test button pressed (manual test of leak mitigation)

Test and repair steps

  1. Wait 1 minute for the test to end, or short-press the test button to end the test.
  2. During the test the blower should run, the compressor/heat should shut off and the alarm relay should operate - use it to verify wiring after installation.
  3. If the code shows without anyone pressing the button, check the button is not stuck.

Settings for these units

Filter sizes by cabinet width · Lennox ML180UHE

CabinetSide returnBottom return
A - 14-1/2 in.16 x 25 x 1 (1)14 x 25 x 1 (1)
B - 17-1/2 in.16 x 25 x 1 (1)16 x 25 x 1 (1)
C - 21 in.16 x 25 x 1 (1)20 x 25 x 1 (1)
D - 24-1/2 in.16 x 25 x 1 (2)24 x 25 x 1 (1)

Filters are field supplied; check monthly.

Cabinet letter is the letter after the cooling size in the model number: A = 045E36AK, 070E36AK; B = 070E36BK, 090E48BK; C = 090E60CK, 110E60CK; D = 135E60DK.

Models that show this code

12 models in Lennox ML180UHE

ML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DK

Other codes on the same units

  • E152 Refrigerant leak sensor #2 fault
  • E154 Refrigerant leak sensor #1 communication lost / wrong DIP setting
  • E155 Refrigerant leak sensor #2 communication lost
  • E160 Refrigerant leak sensor #1 wrong type
  • E161 Refrigerant leak sensor #2 wrong type
  • E163 Furnace control board failure
  • E200 Flame rollout - hard lockout
  • E204 Gas valve miswired

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox ML180UHEK Unit Information 100161/100166, Table 6 Integrated Diagnostic Codes, p.15; Tables 18-19, p.35. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.