Noritz · Tankless water heater

14 Thermal fuse failure

High severity Noritz NRC/NRCPNoritz NRCR

What the control is telling you

The thermal fuse around the heat exchanger/combustion chamber has opened because of overheating. The NRCR deck lists 14 among the codes caused by hard water and scale.

Applies to: Noritz NRC/NRCP and older non-premix, and NRCR

Likely causes

  • Scale build-up in the heat exchanger from hard water
  • Poor combustion overheating the combustion chamber
  • Failed thermal fuse or broken wiring

Test and repair steps

  1. Warning: Find the cause of the overheat before replacing the thermal fuse.
  2. Turn off power, then check the thermal fuse wiring around the heat exchanger for continuity.
  3. Check water hardness; above 12 gpg (200 mg/L) treat or soften the water.
  4. Descale/flush the heat exchanger (see guide 'Descaling (flushing) the heat exchanger - Noritz').
  5. Check combustion gas pressure, venting and burner condition.
  6. Replace the thermal fuse if open and confirm normal operation.

Settings for these units

Indoor clearances (required and recommended) · Noritz NRCR

LocationRequiredRecommended (service)
Top12 in. (300 mm)3 in. (76 mm) above and below exhaust
Front4 in. (100 mm)24 in. (610 mm)
Sides3 in. (76 mm)8 in. (203 mm)

Required clearances apply to both combustible and non-combustible materials.

Recommended space is for service and quick access to gas and water shut-offs.

Operation panel menu settings and defaults · Noritz EZ, Noritz NRCR

SettingOptionsDefault
Max Set Temperature (power off)100-140 F in 5 F steps; 37-48 C, 50-60 C120 F / 50 C
Recirc ON/OFFON / OFFOFF
Recirc ModeAlways OFF, Always ON, Manual Timer, Auto Learning (NRCR)Always OFF
Vacation ModeActive / InactiveInactive
Flow Meter Alarm10-60 gal (5 gal steps), 70-100 gal (10 gal steps), OFFAlarm OFF
Drain Water (power off)Start / CancelCancel
Scale Flushing (power off)Start / CancelCancel
Audible AlarmON / OFFON
Screen LockActive / Inactive (4-digit password)Inactive
Units (first 10 min after power-up, power off)[F/gal/ft] or [C/L/m][F/gal/ft]
Power Saving Dis. / BacklightON-OFF / Power Save ON-OFFON / Power Save ON
Brightness / Contrast / Touch SoundBright-Normal-Dim-Dark / -15 to +15 / ON-OFFNormal / Standard / ON

Setting 125 F (55 C) or higher needs Max Set Temperature raised first; the panel warns about scald risk.

Default Settings resets everything in Settings except Screen Lock (hold OK about 5 s).

Models that show this code

8 models in Noritz NRC/NRCP, Noritz NRCR

N-0841MCN-0841MC-DVN-0842MCN-0842MC-DVNRC111-DVNRC111-SVNRCR111DVNRCR92DV

Other codes on the same units

  • 06 Low recirculation flow (warning only)
  • 10 Abnormal combustion (NRCR, gas supply related)
  • 11 Ignition failure (no flame detected)
  • 12 Flame loss (repeated)
  • 16 Abnormally high outlet temperature
  • 20 High limit switch tripped
  • 29 Condensate collector water level abnormal
  • 061 Recirculation abnormality (sub-code of 06)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Noritz Residential Level 2 Maintenance & Troubleshooting (NRC/NRCP and older, R2 V1), 14, 16, 20 error codes, p.8; Noritz NRCR Pro training (NRCR92/NRCR111, Printable V3), Poor water quality issues, p.32. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.