Midea · Furnace

LED2 green 3 flashes Sensor connected but SW1-2 OFF (DIP reminder)

Low severity Midea 96% AFUE A2L Gas Furnace (BGH96M)

What the control is telling you

The refrigerant sensor is connected and communicating, but drive-board DIP switch SW1-2 is still set to OFF (no sensor).

Applies to: Midea BGH96M 96% AFUE two-stage gas furnaces (060B3A, 080B3A, 080C4A, 100C5A, 100D5A, 120D5A) with A2L refrigerant leak sensor on CN30 (fan drive board LED2)

Likely causes

  • SW1-2 left in OFF position after sensor install

Test and repair steps

  1. Power off the furnace.
  2. Set drive-board DIP SW1-2 to ON (with refrigerant sensor).
  3. Restore power and confirm the LED2 reminder stops.

Models that show this code

6 models in Midea 96% AFUE A2L Gas Furnace (BGH96M)

BGH96M060B3ABGH96M080B3ABGH96M080C4ABGH96M100C5ABGH96M100D5ABGH96M120D5A

Other codes on the same units

  • E6 Limit/rollout switch open more than 5 minutes
  • E7 System lockout - failed ignition
  • E8 System lockout - too many flame dropouts
  • LED2 green 1 flash Refrigerant leak sensor communication failure
  • LED2 green 2 flashes Refrigerant concentration above alarm limit (leak)
  • LED2 green 4 flashes Refrigerant sensor expired or faulty
  • FL Low flame signal
  • Pr Incorrect polarity of L1/L2

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Midea 96% AFUE Gas Furnace (A2L) Troubleshooting Guide, Appendix A3 Requirements for refrigerant leakage sensors, LED2 table, p.27. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.