Lennox · Furnace

E150 A2L refrigerant leak alarm

Critical severity EL296UHVLennox SL280UHVLennox ML180UHE

What the control is telling you

Listed in the 107045-XX table as an A2L refrigerant leak alarm; no corrective action text is given in the manual. The manual (including its troubleshooting section) gives no corrective procedure for this code; steps are general checks only.

Applies to: EL296UHV(X) series furnaces with integrated control 107045-XX only

Likely causes

  • A2L refrigerant leak detected by sensor

Test and repair steps

  1. Treat as a possible refrigerant leak and follow A2L safety practices for the indoor coil/outdoor unit.
  2. Leak-check the indoor coil and line set.
  3. Refer to the A2L sensor and outdoor unit literature; this furnace manual provides no procedure.

Settings for these units

Recommended filter size by cabinet width · EL296UHV

Cabinet widthSide returnBottom return
17-1/2 in.16 x 25 x 1 in. (1)16 x 25 x 1 in. (1)
21 in.16 x 25 x 1 in. (1)20 x 25 x 1 in. (1)
24-1/2 in.16 x 25 x 1 in. (2)24 x 25 x 1 in. (1)

Number in brackets is the quantity of filters.

Filters are field supplied and installed outside the furnace; inspect monthly.

Recommended filter size by cabinet width · Lennox SL280UHV

Cabinet widthSide returnBottom return
14-1/2 in.16 x 25 x 1 in. (1)14 x 25 x 1 in. (1)
17-1/2 in.16 x 25 x 1 in. (1)16 x 25 x 1 in. (1)
21 in.16 x 25 x 1 in. (1)20 x 25 x 1 in. (1)
24-1/2 in.16 x 25 x 1 in. (2)24 x 25 x 1 in. (1)

Number in brackets is filter quantity; filters are field supplied.

Never run the unit without a filter installed.

Models that show this code

30 models in EL296UHV, Lennox SL280UHV, Lennox ML180UHE

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60DML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DKSL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60D

Other codes on the same units

  • E125 Control hardware failure
  • E126 Control internal communication problem
  • E131 Corrupted control parameters
  • E151 A2L sensor fault
  • E152 Refrigerant leak sensor #2 fault
  • E154 Refrigerant leak sensor #1 communication lost / wrong DIP setting
  • E155 Refrigerant leak sensor #2 communication lost
  • E160 Refrigerant leak sensor #1 wrong type

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox EL296UHV(X) Unit Information / Service Literature, Ignition Control 107045-XX Diagnostic Codes table, p.41. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.