44 Human (occupancy) sensor error
What the control is telling you
The occupancy sensor has failed or is disconnected. Indoor lamps: OPERATION (green) flashes 4x, TIMER (orange) flashes 4x, ECONOMY (green) flashes fast nonstop; wired remote shows 44.
Applies to: Fujitsu ductless heat pumps: Fujitsu slim duct ARU 7-18 (LL type)
Likely causes
- Sensor plug
- Sensor fault
Test and repair steps
- Check sensor connector.
- Replace the sensor; then the PCB if needed.
Settings for these units
- Operating range and service space · Fujitsu multi-zone outdoor 18/24 type
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Fujitsu Slim duct AR07-09-12-14-18 (ARU-ARYG LL-type equivalent) installation P-N 9381858064.pdf - section 14 Error codes. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.