Kinghome · Heat pump
E9 Water overflow protection
What the control is telling you
The drain-pan float detected a full pan for 8 s; the unit stops and the wired controller alarms.
Applies to: Kinghome KM09HT1DI, KM12HT1DI, KM18HT1DI, KM24HT1DI wall mini-splits
Likely causes
- Blocked condensate drain
- Drain pump fault
- Faulty float switch
Test and repair steps
- Clear the drain line.
- Check the drain pump operates.
- Test the float switch wiring.
- Restart after the pan empties.
Models that show this code
4 models in Kinghome KM HT1DI
Other codes on the same units
- E4 Compressor discharge temperature too high
- E5 Overcurrent protection
- E6 Indoor/outdoor communication fault
- E8 High temperature resistance (overload) protection
- F0 Refrigerant recovery mode
- F1 Indoor room temperature sensor fault
- F2 Sensor fault (indoor coil or outdoor condenser)
- F3 Outdoor ambient temperature sensor fault
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Kinghome KM09-12-18-24HT1DI service manual, sec. 9.1 error code list. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.