Gree · Heat pump
E7 Mode conflict between indoor units (status)
What the control is telling you
Two or more heads are asking for opposite modes (cooling/dry vs heating, or fan vs heating). The first unit started sets the mode; heating wins over fan mode.
Applies to: Gree Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)
Likely causes
- Indoor units set to different modes
Test and repair steps
- Set all heads to the same mode (or both to compatible modes).
- Explain to the customer that one outdoor unit cannot cool and heat at the same time.
Models that show this code
2 models in Gree Multi21+
Other codes on the same units
- E3 Low pressure protection
- E4 Compressor discharge temperature too high
- E5 Overcurrent protection (whole unit)
- E6 Indoor/outdoor communication fault
- E8 High temperature / overload protection
- F0 Low refrigerant / refrigerant blocked protection
- F1 Indoor room air sensor open or shorted
- F2 Indoor coil sensor open or shorted
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.1 Malfunction status sheet / 9.2 Malfunction Checking and Elimination. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.