Bosch · Tankless water heater
E4 Cabinet air too hot, burner cut off
What the control is telling you
Cabinet air above 176 F (80 C) or above 158 F (70 C) for 2 minutes.
Applies to: Bosch Greentherm T9800 SE 160/199 and T9900 SE 160/199 / i 199 tankless water heaters
Likely causes
- Flue gas leak inside the cabinet or concentric vent
- Faulty cabinet air sensor
Test and repair steps
- Inspect the cabinet interior and the concentric vent for combustion gas escaping.
- Hold the power button down roughly 3 s to clear the stored error.
- Check the cabinet sensor resistance and replace if out of range.
Models that show this code
6 models in Bosch Greentherm T9800 SE, Bosch Greentherm T9900 SE
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch Greentherm T9800 SE 160/199 installation 6720816815 (06.2023), Table 24 Error code diagnostics, p.65-69; Bosch Greentherm T9900 SE 160/199 | i 199 installation 6 720 813 635 (2024-06), section 9.1 Error code diagnostics, p.68-73. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.